EMC CLARiiON AX150 Series Installationsanleitung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
16
Known problems and limitations
EMC AX150-Series Integrated Management Software Release Notes
Description Details
AX150, AX150i, AX150SC, AX150SCi -- During an
upgrade operation a message similar to the following
appears in the event log:
Checking file system on C:
The type of the file system is NTFS.
Volume label is FLARE Partition.
A disk check has been scheduled.
W
indows will now check the disk.
Cleaning up minor inconsistencies on
the drive.
Windows has finished checking your
disk.
Please wait while your computer
restarts.
This is due to an intentionally scheduled run of a
utility to verify that all files were transferred and
installed on the storage system correctly. (83371)
Frequency: Every Time
Prevention/resolution: The message is expected and
should be ignored.
AX150, AX150SC, AX150i, AX150SCi – After
reboot, an SP is not available. Fault LED in the back
is blinking once every 4 seconds.(137693) or 4 times
a second (140661).
Frequency: Extremely Intermittent
Prevention /resolution: Power cycle the storage system.
AX150, AX150i – Failover on a double-faulted
virtual disk results in reservation conflict. (139699)
Frequency: Every time.
Prevention /resolution: Fix the double-faulted virtual disk
before attempting failover.
AX150SC, AX150SCi - Storage system becomes
unresponsive (140698)
Frequency: Extremely Intermittent
Prevention /resolution: Power-cycle the storage system.
Software problems
This section lists known software problems.
Navisphere Storage System Initialization Utility problems
Description Detail
Chinese version of Windows 2003 – It is not
possible to enter IP addresses for the iSCSI data
ports due to an issue with the handling of double-
byte characters.
Frequency: Every Time
Prevention/resolution: Use Navisphere Express to
configure the iSCSI data ports.
Korean version of Windows – The Windows Start -
> Programs menu does not get updated to include
an entry for the storage system initialization utility.
Frequency: Every Time
Prevention/resolution: Run the storage system initialization
utility from its installation directory.