16
Known problems and limitations
EMC AX150-Series Integrated Management Software Release Notes
Description Details
AX150, AX150i, AX150SC, AX150SCi -- During an
upgrade operation a message similar to the following
appears in the event log:
Checking file system on C:
The type of the file system is NTFS.
Volume label is FLARE Partition.
A disk check has been scheduled.
indows will now check the disk.
Cleaning up minor inconsistencies on
the drive.
…
Windows has finished checking your
disk.
Please wait while your computer
restarts.
This is due to an intentionally scheduled run of a
utility to verify that all files were transferred and
installed on the storage system correctly. (83371)
Frequency: Every Time
Prevention/resolution: The message is expected and
should be ignored.
AX150, AX150SC, AX150i, AX150SCi – After
reboot, an SP is not available. Fault LED in the back
is blinking once every 4 seconds.(137693) or 4 times
a second (140661).
Frequency: Extremely Intermittent
Prevention /resolution: Power cycle the storage system.
AX150, AX150i – Failover on a double-faulted
virtual disk results in reservation conflict. (139699)
Frequency: Every time.
Prevention /resolution: Fix the double-faulted virtual disk
before attempting failover.
AX150SC, AX150SCi - Storage system becomes
unresponsive (140698)
Frequency: Extremely Intermittent
Prevention /resolution: Power-cycle the storage system.
Software problems
This section lists known software problems.
Navisphere Storage System Initialization Utility problems
Description Detail
Chinese version of Windows 2003 – It is not
possible to enter IP addresses for the iSCSI data
ports due to an issue with the handling of double-
byte characters.
Frequency: Every Time
Prevention/resolution: Use Navisphere Express to
configure the iSCSI data ports.
Korean version of Windows – The Windows Start -
> Programs menu does not get updated to include
an entry for the storage system initialization utility.
Frequency: Every Time
Prevention/resolution: Run the storage system initialization
utility from its installation directory.
Kommentare zu diesen Handbüchern