Fixed problems
EMC AX150-Series Integrated Management Software Release Notes
Fixed problems
This section identifies issues fixed in various releases.
Hardware problems fixed in version 02.20.150.5.024
Problem Details
AX150SC, AX150SCi, AX150, AX150i – In
very infrequent cases heavy I/O to the same LBA
causes the front-end ports to hang (154617).
Fixed in version: 02.20.150.5.024
Solution: Prevents overlapped I/O from reaching FLARE,
which avoids causing the front-end ports to hang.
AX150, AX150i – System Fault LED does not light
when the UPS serial cable is disconnected (156802).
Fixed in version: 02.20.150.5.024
Solution: Fixed the System Fault LED so that it will light
when the serial cable is not connected.
AX150SC, AX150SCi – System Fault LED does not
light when the wrong cache card (from another
storage system) is installed in the storage system
(156803).
Fixed in version: 02.20.150.5.024
Solution: Fixed the System Fault LED to light when the
wrong cache card is installed.
AX150SCi, AX150i – iSCSI cluster and congestion
issues caused performance problems (159238 and
159278).
Fixed in version: 02.20.150.5. 024
Solution: Fixed iSCSI cluster and congestion issue.
AX150SC, AX150SCi, AX150, AX150i – In
very infrequent cases the storage system does not
power up completely. The SP Fault LED flashes at
1/4 Hz (161139).
Fixed in version: 02.20.150.5. 024
Solution: For every write to I/O port 0x1024 that the BIOS
performs, the BIOS will read in the data at I/O port
0x1024 first. If bits 5, 4, 3, or 2 are set, the BIOS will
increment an error counter and correct the THRM_POL
setting by clearing bits 5, 4, 3, 2 on the write out to IO
port 0x1024.
Hardware problems fixed in version 02.20.150.5.022
Problem Details
AX150SC, AX150SCi – Heavy host I/O to the
storage system causes a cache resource problem,
which causes the storage system to panic. (142940).
Fixed in version: 02.20.150.5.022
Solution: Optimized cache resource allocation to
accommodate heavy I/O and prevent SP panic.
AX150SC, AX150SCi, AX150, AX150i – When
Solaris clustered hosts attempt to trespass a double-
faulted LUN, the storage system returns an event
(reservation conflict) to the cluster that causes the
storage system to panic (139699).
Fixed in vesion: 02.20.150.5.022
Solution: FLARE now returns the proper error to the host
when the condition described occurs.
AX150SC, AX150SCi – Enclosure LED does not
light when the cache card batteries fail to charge.
(150862)
Fixed in version: 02.20.150.5.022
Solution: The enclosure LED now lights when the cache
card batteries fail to charge.