Fixed problems
EMC AX150-Series Integrated Management Software Release Notes
Fixed problems
This section identifies issues fixed in various releases.
Hardware problems fixed in version 02.20.150.5.024
Problem Details
AX150SC, AX150SCi, AX150, AX150iIn
very infrequent cases heavy I/O to the same LBA
causes the front-end ports to hang (154617).
Fixed in version: 02.20.150.5.024
Solution: Prevents overlapped I/O from reaching FLARE,
which avoids causing the front-end ports to hang.
AX150, AX150i – System Fault LED does not light
when the UPS serial cable is disconnected (156802).
Fixed in version: 02.20.150.5.024
Solution: Fixed the System Fault LED so that it will light
when the serial cable is not connected.
AX150SC, AX150SCi – System Fault LED does not
light when the wrong cache card (from another
storage system) is installed in the storage system
(156803).
Fixed in version: 02.20.150.5.024
Solution: Fixed the System Fault LED to light when the
wrong cache card is installed.
AX150SCi, AX150i – iSCSI cluster and congestion
issues caused performance problems (159238 and
159278).
Fixed in version: 02.20.150.5. 024
Solution: Fixed iSCSI cluster and congestion issue.
AX150SC, AX150SCi, AX150, AX150i – In
very infrequent cases the storage system does not
power up completely. The SP Fault LED flashes at
1/4 Hz (161139).
Fixed in version: 02.20.150.5. 024
Solution: For every write to I/O port 0x1024 that the BIOS
performs, the BIOS will read in the data at I/O port
0x1024 first. If bits 5, 4, 3, or 2 are set, the BIOS will
increment an error counter and correct the THRM_POL
setting by clearing bits 5, 4, 3, 2 on the write out to IO
port 0x1024.
Hardware problems fixed in version 02.20.150.5.022
Problem Details
AX150SC, AX150SCi – Heavy host I/O to the
storage system causes a cache resource problem,
which causes the storage system to panic. (142940).
Fixed in version: 02.20.150.5.022
Solution: Optimized cache resource allocation to
accommodate heavy I/O and prevent SP panic.
AX150SC, AX150SCi, AX150, AX150i – When
Solaris clustered hosts attempt to trespass a double-
faulted LUN, the storage system returns an event
(reservation conflict) to the cluster that causes the
storage system to panic (139699).
Fixed in vesion: 02.20.150.5.022
Solution: FLARE now returns the proper error to the host
when the condition described occurs.
AX150SC, AX150SCi – Enclosure LED does not
light when the cache card batteries fail to charge.
(150862)
Fixed in version: 02.20.150.5.022
Solution: The enclosure LED now lights when the cache
card batteries fail to charge.