EMC QLogic Installationsanleitung Seite 48

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 150
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 47
46
EMC Fibre Channel and iSCSI with QLogic Host Bus Adapters in the Windows Environment
Installation and Configuration
By default, option 1 (Enable Hard Loop ID) is disabled.
In FC-SW environments, the default of disabled is the
proper setting.
Select 2. Auto Topology: Pt to Pt first.
Press Enter when your choice has been selected. The
Top ol og y information toward the top of the screen will
reflect your selection.
Press <Escape> to return to the previous configuration
window.
In FC-AL/"direct attach" environments, Hard Loop ID
should be enabled.
Type 1 and press Enter. The utility will prompt to Enable
Hard Loop Id [n]?.
Type y and press Enter. Enable Hard Loop Id will now be
shown as [y] (enabled).
Type 0 and press Enter to return to the previous menu as
shown in Figure 28 on page 45.
Figure 30 Connection option
By default, option 6 (Connection option) setting of Loop
Preferred, Otherwise Point To Point, is acceptable for most
configurations, and will auto-detect the connection topology.
To manually set the connection topology, type 6 and press
Enter. Otherwise, type 0 and press Enter to return to the
previous menu as shown in Figure 28 on page 45.
In FC-SW environments, Point To Point is the appropriate
setting. In FC-AL/"direct attach" environments, Loop Only
should be selected.
Type the appropriate selection and press Enter. The
selected connection topology will now be reflected.
Type 0.