EMC Enterprise StorageEMC Corporation 171 South Street, Hopkinton, MA 01748-9103Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax: (508)
Departmental Switch Models DS-16B and DS-8B Web Tools User GuideTablesx4-7 Remote Tab Fields ...
44-18Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceConfig Admin TabYou can use the Config Admin tab to uploa
4Config Admin Tab4-19Administrative InterfaceFollowing is a description of the fields on the Config Admin tab:Switch Information ReportThe Switch Info
44-20Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceFigure 4-11 Switch Information Report
4Extended Fabric Tab (Optional Software)4-21Administrative InterfaceExtended Fabric Tab (Optional Software)The Extended Fabric feature allows you to c
44-22Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceTable 4-10 describes the fields on the Extended Fabric ta
4Telnet Interface4-23Administrative InterfaceTelnet InterfaceTo access the Telnet Interface, click telnet on the Switch View.Figure 4-13 Initiating a
44-24Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative Interface
Customer SupportA-1Anvisible Body TagThis appendix reviews the EMC process for detecting and resolving software problems, and provides essential quest
AA-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideCustomer SupportSupport ToolIncluded in the switch software is a command that will
AOverview of Detecting and Resolving ProblemsA-3Customer SupportOverview of Detecting and Resolving ProblemsEMC software products are supported direct
Departmental Switch Models DS-16B and DS-8B Web Tools User GuidexiPrefaceThis guide describes Web Tools and provides installation instructions as well
AA-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideCustomer SupportTroubleshooting the ProblemPlease perform the relevant diagnostic
ABefore Calling the Customer Support CenterA-5Customer SupportBefore Calling the Customer Support CenterHave the following information available befor
AA-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideCustomer SupportDocumenting the ProblemIf the EMC Customer Support Center requests
AReporting a New ProblemA-7Customer SupportReporting a New ProblemFor a new problem, please provide the following information:❑ Release level of the s
AA-8Departmental Switch Models DS-16B and DS-8B Web Tools User GuideCustomer SupportSending Problem DocumentationUse one of the following methods to s
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-1GlossaryThis glossary contains terms related to disk storage subsystems. Many of th
g-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossaryASIC Application-Specific Integrated Circuit.ATM Asynchronous Transfer Mode
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-3GlossaryClass 3 A connectionless frame switching service between two ports, without
g-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossaryDLS Dynamic Load Sharing. Dynamic distribution of traffic over available pa
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-5GlossaryFF_Port Fabric Port. A port that can transmit using fabric protocol and can
xiiDepartmental Switch Models DS-16B and DS-8B Web Tools User GuidePrefaceRelated Publications Other publications that provide related information are
g-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossaryFL_Port Fabric Loop Port. A port that can transmit under both fabric protoc
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-7GlossaryGbps Gigabits (1,062,500,000 bits) per second.GBpsGigabytes (1,062,500,000
g-8Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossaryKK28.5 Special 10-bit character used to indicate beginning of transmission
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-9GlossaryMMIB Management Information Base. SNMP structure that provides configuratio
g-10Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossaryinclude frame delimiters (which mark frame boundaries and describe frame c
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-11GlossaryQQuickLoopTMCan indicate either the DS-16B and DS-8B product that allows p
g-12Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossarySwitch A combination of hardware and firmware that routes frames according
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideg-13GlossaryUU_Port Universal Port. Switch port that can operate as G_Port, E_Port, F_
g-14Departmental Switch Models DS-16B and DS-8B Web Tools User GuideGlossary
Departmental Switch Models DS-16B and DS-8B Web Tools User Guidei-1Aadministrative interface 1-4, 1-5Config Admin tab 4-18Extended Fabric tab 4-21A
Departmental Switch Models DS-16B and DS-8B Web Tools User GuidexiiiPrefaceWhere to Get Help Obtain technical support by calling your local sales offi
Departmental Switch Models DS-16B and DS-8B Web Tools User Guidei-2Indexloop diagnostics 3-45loop initialization process (LIP) 3-46Loop tab, Port In
xivDepartmental Switch Models DS-16B and DS-8B Web Tools User GuidePreface
Introducing Web Tools1-11Invisible Body Tag ◆ Overview...
11-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideIntroducing Web ToolsOverviewWeb Tools provides a graphical interface that enables
1Web Tools Views1-3Introducing Web ToolsWeb Tools ViewsWeb Tools provides access to and information about the fabric through a number of separate wind
11-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideIntroducing Web ToolsZone Administration ViewProvides an interface to Zoning, incl
1Web Tools Views1-5Introducing Web ToolsAccessible From Switch View (continued):Port Information ViewDisplays statistics and status for the selected p
Departmental Switch Models DS-16B and DS-8B Web Tools User GuideiiCopyright © 2001 EMC Corporation. All rights reserved.Printed March 2001No part of t
11-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideIntroducing Web Tools
Installing Web Tools2-12Invisible Body Tag This chapter provides the following information:◆ Requirements...
22-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideInstalling Web ToolsRequirementsThe workstation and the switch must both meet spec
2Installation2-3Installing Web ToolsInstallationWeb ToolsWeb Tools software has been preinstalled at the factory. Additional SoftwareIf the following
22-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideInstalling Web Tools5. Click OK.6. Exit and relaunch the browser.Step 2 Browser pa
2Installation2-5Installing Web ToolsStep 3 The correct Browser Process Model must be selected.To select the Browser Process Model:1. Select View, Inte
22-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideInstalling Web Tools2. Follow the link to download the patch, and exit the browser
Using Web Tools3-13Invisible Body Tag This chapter describes the views and interfaces available through Web Tools, which consist of the following:
33-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsFabric ViewThe Fabric View is the first web page that displays when
3Fabric View3-3Using Web ToolsWeb Tools launches, displaying Fabric View (Figure 3-1).Figure 3-1 Fabric ViewTable 3-1 describes the items visible in F
Departmental Switch Models DS-16B and DS-8B Web Tools User GuideiiiJapan:United States:This equipment generates, uses, and may emit radio frequency en
33-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsSummary/Detail View Toggles the Summary or Detail version of Fabric
3Fabric View3-5Using Web ToolsFigure 3-2 illustrates Fabric View with the Summary View selected.polled at or unreachable sinceTime of the last status
33-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsFigure 3-2 Summary Version — Fabric View
3Fabric Events View3-7Using Web ToolsFabric Events ViewThe Fabric Events View provides a running log of events for all switches in the fabric. To acce
33-8Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsTable 3-2 describes the columns in the Fabric Events view. Table 3-
3Fabric Topology View3-9Using Web ToolsFabric Topology ViewThe Fabric Topology View summarizes the physical configuration of the fabric from the persp
33-10Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsFigure 3-4 Fabric Topology ViewThe window can be scrolled downward
3Fabric Topology View3-11Using Web ToolsFigure 3-5 Fabric Topology View, Scrolled DownwardsTable 3-3 describes the fields in the Fabric Topology View.
33-12Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsDestination Domain IDThe ID of the destination domain that is desc
3Name Server Table View3-13Using Web ToolsName Server Table ViewThe Name Server Table View provides the name server entries listed in the Simple Name
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideiv
33-14Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsTo sort the events by a particular column, click the column header
3Name Server Table View3-15Using Web ToolsPort IP Address The IP address of the fabric port.Hard Address The hard address of the fabric port.Member of
33-16Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsZone Administration ViewAdministrative privileges are required to
3Zone Administration View3-17Using Web ToolsFor more information about using Zoning, refer to the Departmental Switches Model DS-16B and DS-8B Zoning
33-18Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsAlias TabYou use the Alias tab (Figure 3-7) to create and manage a
3Zone Administration View3-19Using Web ToolsRename Alias Renames the alias selected in the Alias Name field. A dialog displays in which you can edit t
33-20Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsZone TabYou can use the Zone tab (Figure 3-8) to create and manage
3Zone Administration View3-21Using Web ToolsDelete Zone Deletes the zone selected in the Zone Name field. Deleting a zone automatically removes it fro
33-22Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsQuickLoop TabYou use the QuickLoop tab (Figure 3-9) to create and
3Zone Administration View3-23Using Web ToolsDelete Qloop Deletes the QuickLoop selected in the QuickLoop Name field. Deleting a QuickLoop automaticall
Departmental Switch Models DS-16B and DS-8B Web Tools User GuidevPreface...
33-24Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsFabric Assist TabYou can use the Fabric Assist tab (Figure 3-10) t
3Zone Administration View3-25Using Web ToolsTable 3-10 Fabric Assist Tab FieldsField DescriptionFA Name Modifies an existing Fabric Assist, select a F
33-26Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web Tools[Fabric Assist name] MembersProvides a list of the members that be
3Zone Administration View3-27Using Web ToolsConfig TabYou use the Config tab (Figure 3-11) to create and manage zone configurations. Zone configuratio
33-28Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsDelete Cfg Deletes the configuration selected in the Config Name f
3Switch View3-29Using Web ToolsSwitch ViewThe Switch View represents the front panel of the switch, and displays when you click a Switch icon in Fabri
33-30Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsTable 3-12 describes the items and information available in Switch
3Switch View3-31Using Web ToolsFabric Watch (optional software)Accesses Fabric WatchFan The background color of the button indicates the overall statu
33-32Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsState Indicates the current state of the switch:• online• offline•
3Switch Events View3-33Using Web ToolsSwitch Events ViewThe Switch Events View displays a running log of events for the selected switch. To access Swi
Departmental Switch Models DS-16B and DS-8B Web Tools User GuideviContentsSwitch View ...
33-34Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsTable 3-13 lists available columns in Switch Events View. Table 3-
3Port Information View3-35Using Web ToolsPort Information ViewThe Port Information View displays statistics for the selected port. This information is
33-36Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsThe following tabs are available in Port Information View and are
3Port Information View3-37Using Web ToolsPort Status (continued) Removing a cable from an E_Port temporarily generates errors, causing the status to s
33-38Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsPortStats TabThe PortStats tab provides information about transmis
3Port Information View3-39Using Web ToolsMcast Frames Received Multicast frames received.Mcast Time-outs Multicast timeouts.Mcast Frames Transmitted M
33-40Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsGBIC TabThe GBIC tab provides information about the GBIC (Gigabit
3Port Information View3-41Using Web ToolsTable 3-16 GBIC Tab Fields Field DescriptionIdentifier Indicates the type of serial transceiver, which can be
33-42Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsBR Min Lower limit at which GBIC meets its specifications (in unit
3Port Information View3-43Using Web ToolsLoop TabThe Loop tab (Figure 3-17) provides information about any loop on the port, including the following:◆
Departmental Switch Models DS-16B and DS-8B Web Tools User Guidevii3-1 Fabric View ...
33-44Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsNL Tenancies Number of times NL_Port opens loop tenancy.Number of
3Port Information View3-45Using Web ToolsLoop DiagnosticsDialog BoxThis dialog box displays when you click DIAG on the Loop tab of the Port Informatio
33-46Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsTable 3-18 describes the fields in the Loop Diagnostics dialog box
3Port Information View3-47Using Web ToolsTable 3-20 describes the fields in the Bypass dialog box.Enable Dialog Box You can use the Enable option to e
33-48Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsFabric Watch ViewYou use Fabric Watch View to monitor fabric eleme
3Fabric Watch View3-49Using Web ToolsAlarm Notifications TabYou can use the Alarm Notifications tab (Figure 3-22) to view and customize the Fabric Wat
33-50Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsConfigure ThresholdsYou can use the Configure Thresholds tab to vi
3Fabric Watch View3-51Using Web ToolsThe Configure Threshold display changes according to the class and area selected in the organizational tree. Howe
33-52Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsThresholds for theRemaining ClassesThe Port, E_Port, F/FL Copper P
3Fabric Watch View3-53Using Web ToolsFigure 3-24 displays the thresholds for the Port class.Figure 3-24 Configure Threshold Tab with Port Class Select
viiiDepartmental Switch Models DS-16B and DS-8B Web Tools User GuideFigures4-5 Reboot Switch ...
33-54Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsCurrent Settings Tab The Current Settings tab (Figure 3-25) enable
3Performance View3-55Using Web ToolsPerformance ViewThe Performance View graphically displays throughput (megabytes per second) for each port and also
33-56Departmental Switch Models DS-16B and DS-8B Web Tools User GuideUsing Web ToolsIn addition to the port graphs, a graph for the entire switch is p
Administrative Interface4-14Invisible Body Tag ◆ Administrative Interface...4-2◆ S
44-2Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceAdministrative InterfaceThe Administrative Interface consi
4Administrative Interface4-3Administrative InterfaceFigure 4-1 Enter Network Password4. Enter your user name and password. The logon account must have
44-4Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceSwitch AdministrationUse Switch Administration to change I
4Switch Administration4-5Administrative InterfaceTable 4-1 describes the fields on the Switch Administration tab:Table 4-1 Switch Administration Tab F
44-6Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfacePort Disabled If the box is checked, disables the port. Co
4User Administration4-7Administrative InterfaceUser AdministrationUse User Administration to rename accounts or change passwords.To access User Admini
Departmental Switch Models DS-16B and DS-8B Web Tools User Guideix1-1 Web Tools Views ...
44-8Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceFirmware Upgrade Use Firmware Upgrade to download firmware
4User Administration4-9Administrative InterfaceReboot SwitchUse Reboot Switch to reboot or fast boot the switch. POST (Power On Self Test) can also be
44-10Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceTable 4-4 describes the fields on the Reboot Switch tab:T
4SNMP Administration4-11Administrative InterfaceSNMP AdministrationUse SNMP Administration to set SNMP options.To access SNMP Administration, click th
44-12Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceTable 4-5 describes the fields on the SNMP Administration
4License Administration4-13Administrative InterfaceLicense AdministrationUse License Administration to add or remove licenses. This tab displays a lis
44-14Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceTable 4-6 describes the fields on the License Administrat
4Remote Switch4-15Administrative InterfaceTo access Remote Switch, click the Remote Switch tab from any Administration function.Figure 4-8 Remote Swit
44-16Departmental Switch Models DS-16B and DS-8B Web Tools User GuideAdministrative InterfaceQuickLoop AdministrationUse QuickLoop Administration to s
4QuickLoop Administration4-17Administrative InterfaceTable 4-8 describes the fields on the QuickLoop Administration tab:Table 4-8 QuickLoop Administra